Articles by Gitte Wennecke
Showing articles by "Gitte Wennecke"
Article
June 2021
Point-of-care testing in the Emergency Department - Getting to the point
Introduction
Emergency department (ED) medicine is a specialty that faces unique medical and organizational challenges. Emergency department staff must treat a wide variety of acute injuries and illnesses in a rapid and expedient manner to ensure optimal patient care. This makes logistical organization arguably more...
Point-of-care testing
Process optimization
Article
September 2004
Hematocrit - a review of different analytical methods
To assess anemia and reduced oxygen-carrying
capacity, a measurement of hematocrit and/or hemoglobin is
performed. Whether hemoglobin or hematocrit is preferred
depends on different needs and is often determined by
tradition.
Both hematocrit and hemoglobin are important
hematology parameters for diagnosing...
Preanalytical phase
Quality assurance
Hemoglobins
Kidneys/fluids
Article
July 2004
Useful tips to avoid preanalytical errors in blood gas testing: neonatal total bilirubin
50-75 % of all newborns develop jaundice during their first week of life [1,2,3]. The decision behind which treatment is necessary and when it should be initiated is based upon a measurement of the concentration of total bilirubin (ctBil) in serum, plasma or whole blood.
It is therefore obvious that it is important...
Quality assurance
Bilirubin
Preanalytical phase
Hemoglobins
Blood gases/acid-base
Article
January 2004
Useful tips to avoid preanalytical errors in blood gas testing: metabolites
Measurement of glucose and lactate after 30 minutes of storage at room temperature can give deviating results of up to 5 % [1,2] and 29 % of the reference value [3] respectively [1,4], due to in vitro glycolysis
Glucose and lactate are both important parameters in the surveillance of patients in critical care...
Preanalytical phase
Glucose
Quality assurance
Lactate
Blood gases/acid-base
Article
October 2003
Useful tips to avoid preanalytical errors in blood gas testing: electrolytes
Preanalytical errors are said to be the reason for up to 75 % [1] of all errors in laboratory medicine. The diagnostic consequences depend on the magnitude of the preanalytical error.
In worst case, these errors may lead to mistreatment of patients; in all cases, these errors are an extra workload for the hospital...
Preanalytical phase
Electrolytes
Quality assurance
Glucose
Hemoglobins
Blood gases/acid-base
Article
January 2003
What to consider when performing method comparisons on blood gas analyzers
When performing method comparisons, it is important to address a number of preparatory and preanalytical issues to ensure that comparisons solely reflect the analytical differences between the two methods in question.
This article provides preparatory and preanalytical checklists that can be used when comparing two...
Quality assurance
Blood gases/acid-base
Preanalytical phase